Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Radiat Biol ; 99(1): 77-81, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-32835574

RESUMO

PURPOSE: Monochromatic hard X-rays with high brightness are desired for medical applications including Auger therapy. One can generate such X-rays through laser-Compton scattering (LCS) by allowing photons from a compact laser system to interact with electrons accelerated by a compact electron accelerator. In this paper, after a brief description of laser-Compton X-ray sources, a scheme called crab crossing to enhance the X-ray intensity is proposed. The effect of crab crossing is evaluated, and we report our dedicated laser system for the crab crossing LCS research. MATERIALS AND METHODS: The luminosity enhancement factor by crab crossing is evaluated. For the electron beam, a rf deflector will be used to generate a tilted electron beam. For the laser system, chirped pulsed amplification is adopted. Yb-doped optical fibers and a Yb:YAG thin-disk is used for the laser gain media. RESULTS: The luminosity enhancement factor by crab crossing is expected to be 3.8 when the crossing angle is 45 degrees. 10mJ pulse energy was achieved by thin-disk regenerative amplifier. The pulse duration after the pulse compressor was about 1.5 ps. CONCLUSION: We are going to demonstrate the LCS X-ray enhancement by crab crossing of electron beam and laser pulse. The expected enhancement factor is 3.8. We have successfully finished the laser development and the proof-of-principle experiment will be conducted soon.


Assuntos
Lasers , Luz , Raios X , Radiografia , Fótons
2.
Opt Express ; 30(24): 43888-43899, 2022 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-36523077

RESUMO

Optical enhancement cavities enabling laser pulses to be coherently stacked in free space are used in several applications to enhance accessible optical power. In this study, we develop an optical cavity that accumulates harmonically mode-locked laser pulses with a self-resonating mechanism for X-ray sources based on laser-Compton scattering. In particular, a Fabry-Perot cavity composed of 99% reflectance mirrors maintained the optical resonance in a feedback-free fashion for more than half an hour and automatically resumed the accumulation even if the laser oscillation was suspended. In contrast to conventional optical enhancement cavity systems with a dedicated feedback controller, this characteristic is highly beneficial in practical applications, such as for laser-Compton scattering X-ray sources. Lastly, upscaling and adoption of the proposed system might improve the operability and equipment use of laser Compton-scattering X-ray sources.

3.
Rev Sci Instrum ; 89(2): 023305, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29495841

RESUMO

We describe the stabilization technique of an optical enhancement cavity using a counter propagating mode. The burst amplification of the injection laser in the main path induces a drastic change in the laser intensity and disturbs the stabilization of the enhancement cavity. We have used a counter propagating mode to achieve a 4% intensity jitter and 0.6 mJ pulse storage inside the cavity at the maximum of the burst region. Our results indicate that the counter propagating mode has the same resonant condition as the main mode and thus becomes useful for stabilizing the enhancement cavity. We also determined that the burst amplification brought about no decrease in the enhancement factor in the cavity due to the degradation of laser quality.

4.
J Radiat Res ; 56(5): 768-76, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26141370

RESUMO

We generated low-flux X-ray micro-planar beams (MPBs) using a laboratory-scale industrial X-ray generator (60 kV/20 mA) with custom-made collimators with three different peak/pitch widths (50/200 µm, 100/400 µm, 50/400 µm). To evaluate normal skin reactions, the thighs of C3H/HeN mice were exposed to 100 and 200 Gy MPBs in comparison with broad beams (20, 30, 40, 50, 60 Gy). Antitumor effects of MPBs were evaluated in C3H/HeN mice with subcutaneous tumors (SCCVII). After the tumors were irradiated with 100 and 200 Gy MPBs and 20 and 30 Gy broad beams, the tumor sizes were measured and survival analyses were performed. In addition, the tumors were excised and immunohistochemically examined to detect γ-H2AX, ki67 and CD34. It was shown that antitumor effects of 200 Gy MPBs at 50/200 µm and 100/400 µm were significantly greater than those of 20 Gy broad beams, and were comparable with 30 Gy broad beams. γ-H2AX-positive cells demonstrated clear stripe-patterns after MPB irradiation; the pattern gradually faded and intermixed over 24 h. The chronological changes in ki67 positivity did not differ between MPBs and broad beams, whereas the CD34-positive area decreased significantly more in MPBs than in broad beams. In addition, it was shown that skin injury after MPB irradiation was significantly milder when compared with broad-beam irradiation at equivalent doses for achieving the same tumor control effect. Bystander effect and tumor vessel injury may be the mechanism contributing to the efficacy of MPBs.


Assuntos
Neoplasias/patologia , Neoplasias/radioterapia , Animais , Antígenos CD34/metabolismo , Efeito Espectador , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/radioterapia , Dermatite/etiologia , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Imuno-Histoquímica , Antígeno Ki-67/metabolismo , Camundongos , Camundongos Endogâmicos C3H , Transplante de Neoplasias , Lesões por Radiação , Radiometria , Silício/química , Pele/efeitos da radiação , Fatores de Tempo , Raios X
5.
Phys Rev Lett ; 107(17): 174801, 2011 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-22107525

RESUMO

We represent the first experimental observation of the point spread function (PSF) of optical transition radiation (OTR) performed at KEK-Accelerator Test Facility extraction line. We have demonstrated that the PSF vertical polarization component has a central minimum with a two lobe distribution. However, the distribution width varied significantly with wavelength. We assume that we observed a severe effect from spherical or chromatic aberrations which are not taken into account in any existing theoretical model. We believe that the result of this work will encourage theoreticians to continue developing the theory as it is important for various transition radiation applications. Nonuniform distribution of the OTR PSF creates an opportunity for developing a submicrometer transverse beam size monitor.

6.
Rev Sci Instrum ; 80(12): 123304, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20059137

RESUMO

X-ray generation based on laser-electron Compton scattering is one attractive method to achieve a compact laboratory-sized high-brightness x-ray source. We have designed, built, and tested such a source; it combines a 50 MeV multibunch electron linac with a mode-locked 1064 nm laser stored and amplified in a Fabry-Perot optical cavity. We directly observed trains of pulsed x rays using a microchannel plate detector; the resultant yield was found to be 1.2x10(5) Hz in good agreement with prediction. We believe that the result has demonstrated good feasibility of linac-based compact x-ray sources via laser-electron Compton scatterings.

7.
Phys Rev Lett ; 96(5): 054802, 2006 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-16486939

RESUMO

A free relativistic electron in an electromagnetic field is a pure case of a light-matter interaction. In the laboratory environment, this interaction can be realized by colliding laser pulses with electron beams produced from particle accelerators. The process of single photon absorption and reemission by the electron, so-called linear Thomson scattering, results in radiation that is Doppler shifted into the x-ray and gamma-ray regions. At elevated laser intensity, nonlinear effects should come into play when the transverse motion of the electrons induced by the laser beam is relativistic. In the present experiment, we achieved this condition and characterized the second harmonic of Thomson x-ray scattering using the counterpropagation of a 60 MeV electron beam and a subterawatt CO2 laser beam.

8.
Phys Rev Lett ; 93(24): 244802, 2004 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-15697821

RESUMO

An experiment on the investigation of optical diffraction radiation (ODR) from a slit target as a possible tool for noninvasive electron beam-size diagnostics has been performed at the KEK accelerator test facility. The experimental setup has been installed at the diagnostics section of the extraction line. We have performed the first incoherent ODR observation from a slit target. The measured angular distributions are in reasonable agreement with the theoretical expectation. The beam-size effect onto the ODR angular pattern has been observed. Moreover, the sensitivity to the beam size as small as 14 microm has been achieved.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...